 CR08AS
Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (412) 925-7272
Surface Mount, Phase Control SCR
0.8 Amperes/400-600 Volts
OUTLINE DRAWING
A E
F
D B
H G C K J
L
Description: The Powerex CR08AS Phase Control SCRs are glass passivated thyristors for use in low power control and rectification. These devices are molded epoxy plastic types. Features: Surface Mount Type
CONNECTION DIAGRAM
Glass Passivated
CATHODE ANODE GATE
Gate Trigger Current is Small Easy Application for Printed Circuits Applications: Solid State Relay Static Switches Ignitors Strobe Flasher Ordering Information: Example: Select the complete seven or eight digit part number you desire from the table - i.e. CR08AS-8 is a 400 Volt, 0.8 Ampere Phase Control SCR.
Type CR08AS VDRM/VRRM Volts 400 600 Code -8 -12
Outline Drawing (Conforms to SOT-89) Dimensions A B C D E F Inches 0.18 Max. 0.17 Max. 0.12 0.10 0.004 0.06 0.008 0.06 0.004 Millimeters 4.6 Max. 4.2 Max. 3.0 2.5 0.1 1.6 0.2 1.5 0.1 Dimensions G H J K L Inches 0.06 0.031 Min. 0.021 Max. 0.019 Max. Millimeters 1.5 0.8 Min. 0.58 Max. 0.48 Max.
0.016+0.001/-0.002 0.4+.03/-.05
P-17
Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (412) 925-7272 CR08AS Surface Mount, Phase Control SCR 0.8 Amperes/400-600 Volts
Absolute Maximum Ratings, Ta = 25 C unless otherwise specified
Ratings Repetitive Peak Off-state Voltage Repetitive Peak Reverse Voltage Non-repetitive Peak Reverse Voltage DC Reverse Voltage DC Forward Voltage RMS On-state Current Average On-state Current (Nominal, See Graphs) Ta = 51C I2t for Fusing, t = 8.3 msec Peak Gate Power Dissipation Average Gate Power Dissipation Peak Forward Gate Current Peak Forward Gate Voltage Peak Reverse Gate Voltage Storage Temperature Operating Junction Temperature Weight Symbol VDRM VRRM VRSM VR(DC) VD(DC) IT(RMS) IT(avg) I2t PGM PG(avg) IFGM VFGM VRGM Tstg Tj - CR08AS-8 (Marked "AD") 400 400 500 320 320 1.26 0.8 10 0.42 0.5 0.1 0.3 6 6 -40 to 125 -40 to 125 48 CR08AS-12 (Marked "AF") 600 600 720 480 480 1.26 0.8 10 0.42 0.5 0.1 0.3 6 6 -40 to 125 -40 to 125 48 Units Volts Volts Volts Volts Volts Amperes Amperes Amperes A2sec Watts Watts Amperes Volts Volts C C mg
Non-repetitive Peak Surge, On-state Current One Cycle (60 Hz) ITSM
P-18
Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (412) 925-7272 CR08AS Surface Mount, Phase Control SCR 0.8 Amperes/400-600 Volts
Electrical and Thermal Characteristics, Tj = 25 C unless otherwise specified
Characteristics Voltage - Blocking State Peak Forward Leakage Peak Reverse Leakage Current - Conducting State Peak On-state Voltage DC Holding Current Thermal Resistance, Junction-to-ambient Gate - Parameters Gate Current to Trigger* Gate Voltage to Trigger Non-triggering Gate Voltage
I ,V GT GT Measurement Circuit
Symbol IDRM IRRM VTM IH Rth(j-a) IGT VGT VGD
Test Conditions Tj = 125C, VD = VDRM Tj = 125C, VR = VRRM Tc = 25C, ITM = 2.5A VD = 12V, RGK = 1K , Tj = 25C - VD = 6V, RL = 60 , Tj = 25C VD = 6V, RL = 60 , Tj = 25C VD = 1/2VDRM, RGK = 1k , Tj = 125C
Min. - - - - - - - 0.3
Typ. - - - 1.5 - - - -
Max. 0.5 0.5 1.5 3.0 65 100 0.8 -
Units mA mA Volts mA C/Watt A Volts Volts
* If special values of IGT are required, choose at least two items from those listed in the table below; i.e. A-B or B-C. Item IGT ( A) A 1-30 B 20-50 C 40-100
IGS A3 3V DC
IGT A2 V1 VGT
A1 TUT
60 6V DC
RGK 1 2 1k SWITCH
SWITCH 1: IGT Measurement SWITCH 2: VGT Measurement (Inner resistance of voltage meter is about 1k )
P-19
Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (412) 925-7272 CR08AS Surface Mount, Phase Control SCR 0.8 Amperes/400-600 Volts
MAXIMUM ON-STATE CHARACTERISTICS
TRANSIENT THERMAL IMPEDANCE, Zth(j-a), (C/WATT) INSTANTANEOUS ON-STATE VOLTAGE, VT, (VOLTS)
5
Tj = 25oC
10
0 310
TRANSIENT THERMAL IMPEDANCE CHARACTERISTICS (JUNCTION-TO-AMBIENT) 101 102 25 x 25 x t0.7 ALUMINUM BOARD
103
GATE CHARACTERISTICS
102
Tj = 25
GATE VOLTAGE, VG, (VOLTS)
4
101
VFGM = 6V
PGM = 0.5W PG(avg) = 0.1W
102
3
100
VGT = 0.8V IGT = 100 A VGD = 0.2V IFGM = 0.3A
2
101
10-1
1
0 10-1
100
101
102
100 10-3
10-2
TIME, t, (S)
10-1
100
10-2 10-2
10-1
100
101
102
INSTANTANEOUS ON-STATE CURRENT, IT, (AMPERES)
GATE CURRENT, IG, (mA)
MAXIMUM SURGE CURRENT FOLLOWING RATED LOAD CONDITIONS
MAXIMUM PEAK SURGE CURRENT, ITSM, (AMPERES)
ALLOWABLE AMBIENT TEMPERATURE VS. AVERAGE ON-STATE CURRENT (SINGLE-PHASE HALF WAVEFORM)
ALLOWABLE AMBIENT TEMPERATURE VS. AVERAGE ON-STATE CURRENT (SINGLE-PHASE HALF WAVEFORM)
10
160 140
RESISTIVE, INDUCTIVE LOADS NATURAL CONVECTION = 180
160 140
AMBIENT TEMPERATURE, Ta, (C)
360
8
AMBIENT TEMPERATURE, Ta, (C)
RESISTIVE, INDUCTIVE LOADS NATURAL CONVECTION
360
120 100 80 60 40
120 100 80
= 30
6
65C/W
25 x 25 x t0.7 ALUMINUM BOARD
4
90C/W Rth(j-a) = 200C/W
60 40 20 0
60 90 120 180
2
20 0 100 0 101
CYCLES AT 60 Hz
102
0
0.2
0.4
0.6
0.8
0
0.4
0.8
1.2
1.6
AVERAGE ON-STATE CURRENT, I T(avg), (AMPERES)
AVERAGE ON-STATE CURRENT, I T(avg), (AMPERES)
MAXIMUM ON-STATE POWER DISSIPATION (SINGLE-PHASE HALF WAVEFORM)
ALLOWABLE AMBIENT TEMPERATURE VS. AVERAGE ON-STATE CURRENT (SINGLE-PHASE FULL WAVEFORM)
MAXIMUM ON-STATE POWER DISSIPATION (SINGLE-PHASE FULL WAVEFORM)
1.6
MAXIMUM POWER DISSIPATION, (WATTS)
160
MAXIMUM POWER DISSIPATION, (WATTS)
1.6
RESISTIVE LOADS NATURAL CONVECTION ALUMINUM BOARD 25 X 25 X t0.7
60
1.4 1.2 1.0 0.8 0.6 0.4 0.2 0 0 0.4 0.8 1.2 1.6
AVERAGE ON-STATE CURRENT, IT(avg), (AMPERES)
360
140
AMBIENT TEMPERATURE, Ta, (C)
1.4 1.2 1.0 0.8 0.6 0.4 0.2 0 0
60 = 30 90 120 180
= 30 90 120 180 RESISTIVE, INDUCTIVE LOADS
120 100 80 60 40
360
120
360
20
= 30 60 90 180
RESISTIVE LOADS
0 0 0.4 .08 1.2 1.6
AVERAGE ON-STATE CURRENT, IT(avg), (AMPERES)
0.4
0.8
1.2
1.6
AVERAGE ON-STATE CURRENT, IT(avg), (AMPERES)
P-20
Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (412) 925-7272 CR08AS Surface Mount, Phase Control SCR 0.8 Amperes/400-600 Volts
MAXIMUM ALLOWABLE AMBIENT TEMPERATURE (RECTANGULAR WAVEFORM)
MAXIMUM ALLOWABLE AMBIENT TEMPERATURE, Ta, (C)
MAXIMUM ON-STATE POWER DISSIPATION (RECTANGULAR WAVEFORM)
GATE TRIGGER CURRENT VS. JUNCTION TEMPERATURE (TYPICAL)
160
MAXIMUM POWER DISSIPATION, (WATTS)
1.6 1.4 1.2 1.0 0.8 0.6 0.4 0.2 0 0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6
GATE TRIGGER VOLTAGE VS. JUNCTION TEMPERATURE (TYPICAL)
360
103
GATE TRIGGER CURRENT, (tC) x 100% GATE TRIGGER CURRENT, (25C)
140 120 100 80 60 40 20
RESISTIVE, INDUCTIVE LOADS NATURAL CONVECTION
360
= 30 60 90 120 180 270 DC
102
60 90 120 180
25 x 25 x t0.7 ALUMINUM BOARD
101
= 30
270
DC
RESISTIVE, INDUCTIVE LOADS
0
AVERAGE ON-STATE CURRENT, IT(avg), (AMPERES)
0
0.4
0.8
1.2
1.6
100 -40
0
40
80
120
160
AVERAGE ON-STATE CURRENT, IT(avg), (AMPERES)
JUNCTION TEMPERATURE, Tj, (C)
HOLDING CURRENT VS. JUNCTION TEMPERATURE (TYPICAL)
HOLDING CURRENT VS. GATE TRIGGER CURRENT
1.0
GATE TRIGGER VOLTAGE, (VOLTS)
102
RGK = 1k
HOLDING CURRENT, IH, (mA) HOLDING CURRENT, IH, (mA)
4.0
Ta = 25C
0.8
DISTRIBUTION
3.5 3.0 2.5 2.0 1.5 1.0 0.5
101
0.6
DISTRIBUTION TYPICAL EXAMPLE
0.4
TYPICAL EXAMPLE
100
0.2
0 -40
10-1 0 40 80 120 -40 0 40 80 120 160
JUNCTION TEMPERATURE, Tj, (C) JUNCTION TEMPERATURE, Tj, (C)
0 100
101
102
103
GATE TRIGGER CURRENT, IGT, (mA)
HOLDING CURRENT VS. GATE-TO-CATHODE RESISTANCE (TYPICAL)
BREAKOVER VOLTAGE VS. JUNCTION TEMPERATURE (TYPICAL) RGK = 1k
x 100%
BREAKOVER VOLTAGE VS. RATE OF RISE OF OFF-STATE VOLTAGE (TYPICAL)
500
x 100% BREAKOVER VOLTAGE, (tC) x 100% BREAKOVER VOLTAGE, (25C)
160
160 140 120 100 80 60 40 20 0 100 101 102 103
Tj = 125C RGK = 1k
HOLDING CURRENT, (RGK = 1k )
HOLDING CURRENT, (RGK = rk )
120
300
80
200
100
40
0 10-1
0 100 101 102 -40 0 40 80 120 160
GATE-TO-CATHODE RESISTANCE, RGK, (k ) JUNCTION TEMPERATURE, Tj, (C)
BREAKOVER VOLTAGE, (dv/dt = x V/ s) BREAKOVER VOLTAGE, (dv/dt = 1V/ s)
400
RATE OF RISE OF OFF-STATE VOLTAGE, dv/dt, (V/ s)
P-21
Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (412) 925-7272 CR08AS Surface Mount, Phase Control SCR 0.8 Amperes/400-600 Volts
BREAKOVER VOLTAGE VS. GATE TO CATHODE RESISTANCE (TYPICAL)
REPETITIVE PEAK OFF-STATE CURRENT VS. JUNCTION TEMPERATURE (TYPICAL)
REPETITIVE PEAK OFF-STATE CURRENT, (tC) x 100% REPETITIVE PEAK OFF-STATE CURRENT, (25C)
GATE TRIGGER CURRENT VS. GATE CURRENT PULSE WIDTH (TYPICAL)
160
x 100%
160
GATE TRIGGER CURRENT, (tw) x 100% GATE TRIGGER CURRENT, (DC)
105
140 120 100 80 60 40 20
Tj = 125C
BREAKOVER VOLTAGE, (RGK = rk ) BREAKOVER VOLTAGE, (RGK = 1k )
120
tw
104
0.1 s
80
103
40
0 10-1
100
101
102
0 -40
0
40
80
120
160
102 100
101
102
103
GATE TO CATHODE RESISTANCE, RGK ,(k )
JUNCTION TEMPERATURE, Tj, (C)
GATE CURRENT PULSE WIDTH, tw, ( s)
TURN-OFF TIME VS. JUNCTION TEMPERATURE (TYPICAL)
TURN-ON TIME VS. GATE CURRENT (TYPICAL)
THERMAL IMPEDANCE VS. BOARD DIMENSIONS
40 35
TURN-OFF TIME, Tq, ( s)
102
VD = 50V VR = 50V IT = 2A RGK = 1k Ta = 25C VD = 100V RL = 47 RGK = 1k Ta = 25C
TURN-ON TIME, tgt, ( s)
320 280
THERMAL IMPEDANCE, (C/W)
30 25 20 15 10 5 0 0
DISTRIBUTION
240
WITHOUT EPOXY PLATE
101
200 160 120 80 40
t0.7 ALUMINUM BOARD 10 X 10 EPOXY PLATE WITH COPPER FOIL
100
TYPICAL EXAMPLE
20
40
60
80 100 120 140 160
10-1 10-1
0 100 101 102 0 10 20 30 40 50 60 70 80
GATE CURRENT, IGT, (mA) BOARD DIMENSIONS, (mm) REGULAR SQUARE ONE SIDE
JUNCTION TEMPERATURE, Tj, (C)
P-22


▲Up To Search▲   

 
Price & Availability of CR08AS400-12

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X